Sugar Reports: An IU Turbidity Result Is Not a Colour Result

A sugar certificate can contain more than one result reported in ICUMSA units. Copying the unit into a purchasing spreadsheet without the property name can turn a turbidity result into an apparent colour result. The smaller number then looks attractive for the wrong reason.

Keep the measured property beside the unit

ICUMSA’s public abstract for GS2-18 (2013) describes a turbidity measurement for white sugar solutions with colour below 50 IU. It derives the result from the difference between colour measurements of filtered and unfiltered solutions and reports the turbidity in IU. The unit therefore does not identify the property on its own.

This matters when a certificate, translated report or quotation is reduced to a single field called “ICUMSA value.” Before comparing that field with a contract limit, recover the laboratory’s full parameter name, method identifier, edition and reporting unit. Do not infer the missing name from the commercial sugar grade.

Reference: ICUMSA GS2-18 (2013): turbidity of white sugar solutions

A colour method answers a separate question

For comparison, the public GS2-10 (2024) abstract describes colour in solution, using a filtered solution measured by spectrophotometry. Its stated applicability and limitations belong to that method. A report naming GS2-18 should not be relabelled GS2-10 merely because both lines may use IU.

The laboratory and the buyer’s technical team should confirm which methods fit the material and the agreed requirements. This article identifies the reporting distinction; it does not supply the complete laboratory procedures or establish a universal colour or turbidity acceptance limit.

Reference: ICUMSA GS2-10 (2024): colour in solution

Do not rank unlike certificate lines

Consider a hypothetical comparison: one report states solution colour of 18 IU, while another states turbidity of 4 IU. These are teaching figures, not offered-lot results or recommended specifications. The second figure cannot establish that its sugar has the lower solution colour. The reports have not yet supplied comparable evidence for that question.

Ask for the missing result if it is required by the purchase specification. Keep the original certificate attached and label any working summary accurately. Do not add, subtract or otherwise combine independently reported figures to invent an unreported acceptance result; the method and the laboratory’s explanation must govern the interpretation.

Build a certificate check that preserves both meanings

Use separate rows for solution colour and turbidity wherever both are contracted. Each row should retain the property, result, unit, method, sample reference and its own acceptance requirement. A shared lot reference can connect the rows without merging their meanings.

If a supplier provides only a product brochure or typical analysis, identify it as such. For a shipment release decision, establish what lot-specific evidence the contract requires, where the sample is taken and who reviews an unclear or conflicting result. A result should not acquire broader authority simply because it has been entered into the buyer’s system.

State the evidence requirement in the sugar enquiry

Send the intended application, sugar form, separately defined analytical requirements, quantity, packing, destination and delivery basis. If turbidity matters to the buyer’s process, ask the technical team to define the applicable method and acceptance rule before requesting comparable offers. A colour grade alone does not complete that instruction.

Zenith Eclipse’s sugar page describes grade-first enquiries and lot-linked quality evidence where contracted. Current source availability, the nominated product and the final analytical specification require written confirmation. Clear certificate fields help the buyer review that offer without mistaking one IU result for another.

Reference: Zenith Eclipse: sugar supply and buying requirements

Discuss your requirements

Request a specification-based sugar offer

Send the sugar form, separate analytical requirements, quantity, packaging and destination for a shipment-specific supply review.

sales@zenitheclipse.com

Explore all Insights